Configure syslog server on F5 BIG-IP

Syslog servers are a great idea they centralise all your logs from your Servers and networking devices.

I used for the syslog server the following command

bigpipe syslog remote server 'syslog-srv.local-domain.com' host 10.1.1.100 add

After that everything looked fine and I saw syslog messages but I got lots of informational messages and the following debug message.

debug snmpd[PID]: error on subcontainer 'ia_addr' insert (-1)

For the debug message I found a solution on AskF5: http://support.f5.com/kb/en-us/solutions/public/12000/100/sol12136.html?sr=16487442

There is saw that I went the wrong way of configuring syslog on my load balancer, I also needed to set the log level for remote syslog server. Here the solution from F5: http://support.f5.com/kb/en-us/solutions/public/11000/700/sol11723.html

1. Log in to the command line of the BIP-IP

2. Create in /tmp/syslog.inc file with the syslog configuration.

syslog include "
filter f_remote_loghost {
level(notice..emerg);
};
destination d_loghost {
udp(\"10.1.1.100\" port(514));
};
log {
source(s_syslog_pipe);
filter(f_remote_loghost);
destination(d_loghost);
};
"

3. To remove the currently configured remote syslog servers, type the following command:
Important: This step disables all remote logging.

[root@l-ltm-ve-01:Active] tmp # b syslog remote server none

4. Copy the changes into the configuration

[root@l-ltm-ve-01:Active] tmp # bpsh < /tmp/syslog.inc

5. Refresh and start syslog deamon

[root@l-ltm-ve-01:Active] tmp # syslog-ng -s

6. Save the configuration

[root@l-ltm-ve-01:Active] tmp # b save all
/config/bigip_base.conf was renamed to /config/bigip_base.conf.bak (86 lines).
/config/bigip_sys.conf was renamed to /config/bigip_sys.conf.bak (66 lines).
/config/bigip.conf was renamed to /config/bigip.conf.bak (894 lines).
/config/bigip_local.conf was renamed to /config/bigip_local.conf.bak (1 lines).
[root@l-ltm-ve-01:Active] tmp #

If the new logging configuration is not working as expected, make the desired changes to the /tmp/syslog.inc file and return to Step 2.

When the syslog-ng -s command reports the following error message:

# syslog-ng -s syntax error at 751

Remove the syslog include entries by typing the following command:

bigpipe syslog include none

Review the import configuration for syntax errors before attempting to re-import by typing the command listed in Step 2.

F5 iRule for layer 7 balancing

This is an iRule for F5 BIGIP to balance on the requested http path, so http://domain.com/appversion1-0 or http://domain.com/appversion2-0 . The benefit is that you have different server pools under the same domain.

With the iRule you can also access every member and open a status.txt or servername.txt with the following path http://domain.com/monitor/servername.txt?app=appversion1-0&node=1 .  This option is for monitoring reasons as you can monitor every node over the external URL.

I also use the status.txt for an http monitor to see if the server is online or offline. You can use that to set the web server offline without doing that over the F5 management console.

GET /monitor/status.txt HTTP/1.1\r\nHOST:\r\nConnection: Close\r\n\r\n
Enable: ONLINE
Disable: OFFLINE

In the servername.txt I write the name of the server.

This is the iRule:

when HTTP_REQUEST {
switch -glob [string tolower [HTTP::path]] {
"*appversion1-0*" { pool pool_http80_domain.com-appversion1-0}
"*appversion2-0*" { pool pool_http80_domain.com-appversion2-0}
"*monitor*" {

switch [URI::query [HTTP::uri] "app"] {
appversion1-0 {
switch [URI::query [HTTP::uri] "node"] {
1 { pool pool_http80_domain.com-appversion1-0 member 10.0.1.1 80 }
2 { pool pool_http80_domain.com-appversion1-0 member 10.0.1.2 80 }

default { HTTP::respond 200 content "<html><head><title>Member Status</title></head><body>INVALID OR MISSING QUERYSTRING: You must enter the URL in the following format http://domain.com/monitor/(status|servername).txt?app=AppVersionNumber&node=NodeNumber" "Content-Type" "text/html" }

}
}

appversion2-0 {
switch [URI::query [HTTP::uri] "node"] {
1 { pool pool_http80_domain.com-appversion2-0 member 10.0.2.1 80 }
2 { pool pool_http80_domain.com-appversion2-0 member 10.0.2.2 80 }

default { HTTP::respond 200 content "<html><head><title>Member Status</title></head><body>INVALID OR MISSING QUERYSTRING: You must enter the URL in the following format http://domain.com/monitor/(status|serversame).txt?app=AppVersionNumber&node=NodeNumber" "Content-Type" "text/html" }

}
}

default { HTTP::respond 200 content "<html><head><title>Member Status</title></head><body>INVALID OR MISSING QUERYSTRING: You must enter the URL in the following format http://domain.com/monitor/(status|servername).txt?app=AppVersionNumber&node=NodeNumber" "Content-Type" "text/html" }

}
}

default { pool pool_http80_domain-appversion1-0 }

}
}

The default app pool is appversion1-0 so everything that didn’t match is forwarded to that pool.

F5 BIGIP Software upgrade procedure

Here is a procedure on how to upgrade the software on an F5 BIGIP cluster tier.

  1. Download last ISO version for F5 BIGIP LTM
  2. Upload the ISO to the standby unit
  3. Install the ISO to a free partition on the standby unit
  4. Change boot location to the new partition and device automatically reboots.

After 6 to 7 minutes the device booted with the new software version. From now on you won’t be able to sync your configs between the devices anymore because of the different software versions it’s only possible within the same release. F5 doesn’t recommend to run cluster with different software versions.

Now initiate the failover on the active unit! Do that maybe at low traffic period! Normally there should be no side effect and the failover is not visible to clients because of the mirroring the sessions.

In case of problems with the new software version you should be able to switch back to the other cluster member with the old software version at any time.

  1. When you verify that everything is working after the failover you can start the other device now
  2. Upload ISO file
  3. Install ISO file
  4. Change boot location

The same procedure you use to install hotfixes on the BigIP.

F5 Load Balancer

My company decided to buy two F5 Big IP Local Traffic Manager 8950 for our web cluster systems with a maximum balanced capacity of 20 gigabit. We also got the F5 Local Traffic Manager as Virtual Edition for our test enviroment and to integrate it into the test network.

In the beginning the F5 looked very complicated but after some time now playing around with it and setting up things, it got easier and easier. I only need to have a deeper look at the iRules because this feature allows you can to really do everything with the F5 load balancer.

So for now I can’t really write more about it but I will soon  post some updates.

Next week I have the integration of the F5 Big-IP into the production network of my company and will start setting up the first new linux web cluster but only with a layer 4 balancing.

Update:

Here a nice picture of the new F5 BigIP boxes in the data center from my company:

For the new web cluster for my company we set-up layer 4 balanced web server pools and layer 7 balanced pools.

The layer 7 balancing was necessary because there where different server pools with applications that needed to run under the same domain and where routed on the expected http/https request. I will post the iRule for everybody soon.

Here two interesting ressources to get information:

Ask F5

F5 Devcentral